-40%

FIELDPIECE CHARGING KIT #ASX14

$ 102.96

Availability: 100 in stock
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Item must be returned within: 14 Days
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: FIELDPIECE

    Description

    BRAND NEW
    Fieldpiece Superheat and Subcooling Accessory for Air Conditioning, Model ASX14
    Specifications:
    ~ Operating environment: 32ºF to 122ºF; 0ºC to 50ºC at <75%RH
    ~Allow ~5 min. for ASX14 to come to ambient temp.
    ~Storage environment: -4ºF to 140ºF; -20ºC to 60ºC at <80%RH with battery removed.
    ~Battery life: 25 hours typical. No measurable current draw when in "off" position.
    ~Low battery indication: Red LED lights
    ~Battery: 9V
    ~Auto off: Approx. 15 minutes
    ~Overloads: The ASX14 outputs 3.4V when temperature or pressure is outside of their working range (overloaded). For ranges below 3400mVDC, the normal overload symbol will be displayed on the meter (“OL”). For ranges above 3400mVDC, reading displayed will be approximately 3.4VDC.
    ~ Stated Accuracy: at 73°F ± 9°F (23°C ±5°C) <90% R.H.
    Compatible Refrigerants
    Built-in Pressure/Temperature Charts:  R22, R410A.  PT charts for 12 refrigerants when used with HVAC Guide® System Analyzer.
    Temperature:
    ~Range (temperature): -40ºF to 400ºF; -40ºC to 204ºC
    ~Resolutions: 0.1º
    ~Sensor type: k-type thermocouple
    ~Pipe clamp thermocouple accuracy: ±4ºF (±2°C) or ±0.75%, whichever is greater, -30ºF to    200ºF (-34°C to 93°C)
    ~System accuracy: ±1ºF;±0.06ºC @ 73ºF ± 5ºF after ice water calibration (see Field calibration).
    Pressure and vacuum:
    ~Working range (pressure): 0 to 500 psi; 0 to 4000 kPa
    ~Max displayed pressure: 800psi (5500 kPa)
    ~Working range (vacuum): 29”Hg vac. to 0; 74cmHg vac. to 0
    ~Vacuum will show up as negative value on meter.
    ~Resolutions: 0.1psi or kPa, 0.1”Hg or cmHg vac.
    ~Accuracy: 0 to 200 psig, ±1 psi, 0 to 1378 kPa ±6.9 kPa; 200 to 500 psig, 0.3% ±1 psi, 1378 to 3447 kPa 0.3% ±6.9kPa
    ~Sensor breakdown pressure: 800psi (5500 kPa)
    Superheat:
    ~Range (temperature): 0ºF to 80ºF; 0ºC to 27ºC
    ~Resolutions: 0.1º
    ~System Accuracy: ±1ºF @ 73ºF ± 5ºF (±0.06ºC @ 23°C ±3°C) after calibration (see Field calibration).
    Subcooling:
    ~Range (temperature): 0ºF to 80ºF; 0ºC to 27ºC
    ~Resolutions: 0.1º
    ~System Accuracy: ±1ºF @ 73ºF ± 5ºF (±0.06ºC @ 23°C ±3°C) after calibration (see Field calibration
    Included:
    ~ Superheat and Subcooling Accessory for Air Conditioning - ASX14
    ~ Pipe-Clamp Thermocouple 3/8” to 1 3/8” for Air Conditioning - ATC1
    ~ 9V battery (installed)
    ~ Operator’s manual
    PAYMENT POLICY
    - We currently accept credit card, electronic checks, and direct payment via Paypal
    - Payment must be received within 7 days of the sale date.
    - We reserve the right to cancel a purchase if payment is not received.
    - If payment cannot be made within the required time frame. Please contact us to make other arrangements.
    - In the case of electronic check payments via Paypal, no further action will be taken on the order until payment is cleared.
    - Cash on delivery can be an acceptable form of payment for local pick up or delivery.
    SHIPPING
    - Reqular sized items will be handle within 1 business day (unless stated otherwise) of a completed checkout (a completed checkout is constituted by a purchase and payment).
    - Bulk items and oversized items may need additional handling time which will be stated in the listing.
    - Shipping is free on all purchases (unless stated otherwise).
    - In the case of local purchases, we may choose to deliver the products ourselves (per our discretion).
    RETURNS
    - Most items are covered by manufacturer’s warranty.
    - However, returns are accepted within 14 days on all items (unless otherwise stated).
    - In the case of faulty items, all returns are accepted as long as we are notified within a reasonable time frame.
    - Electrical units are final sale and are non-refundable.
    - To begin processing a return, please contact us via eBay message.
    - This item is final sale and is NON-REFUNDABLE.